PV Solar Surge Protective Device(DC SPD)

HSP-D40 (T2)
2P 20-40KA
500V/600V/800V/1000V DC

HSP-D40 (T2)
3P 20-40KA
1000V/1500V DC

HSP-D40(T1+T2)
2P 20-40KA
600V DC

HSP-D40(T1+T2)
3P 20-40KA
1000V/1500V DC
Safety & Compliance:
Built-in thermal disconnector and fault indicator. Tested to EN50539-11.
Design:
Modular plug-in for fast replacement; DIN rail mountable.
Versatility:
1000V / 1500V DC, Type 2 or Type1+2.
Applications:
• Solar PV DC combiner boxes
• Inverter DC side protection
Dimensions & Typical Wiring


Critical Wiring Guidelines
- Mandatory Overcurrent Protection: Install DC fuse/MCB upstream of SPD to cut circuit on SPD failure and avoid fire risk.
- Earthing: PE wire ideally ≤0.5m, copper cable 6–16mm². Connect SPD directly to equipotential bonding bar.
- Polarity: PV positive to L+, negative to L-. Reverse polarity damages internal MOV.
- DIN Rail: Mount SPD, fuse and MCB on standard 35mm DIN rail.
- Load: Each PV string with separate output MCB for partial maintenance.
- Replacement: Pluggable cartridge, replace without disconnecting full DC bus.